WALL SYSTEM 1 APPLIED TO BLOCKWORK

 

 

 

 

 

 

 

 

Click here for Detailed Diagram

 
 
 
  WALL SYSTEM 1 APPLIED DIRECTLY TO CEMENT PARTICLE BOARD  
   




SPECIFICATION

• 15mm Firecheck
• 100mm Lightweight Steel Studs Containing 50mm
  Rockwool Flexi
• 10mm Cement Particle Board
• 3mm-5mm Granol G Adhesive Mortar
• 80mm EPS with mineral wool fire breaks or 80mm
  External Wall Slab HD
• Ejot SBHT 4.8 x 80 Fixing and nylon washer
• 3mm-5mm Granol-G Basecoat incorporating Plastic
  coated glass fibre reinforcing mesh
• Granol Acrylic or Silicone primer
• Granol Silicone or Acrylic Top coat

THERMAL
• Minimum U-Value 0.3 W/(m2K) 70mm EPS

ACOUSTIC
• Minimum sound insulation RwdB 50dB sound reduction

FIRE
• 30 minutes fire resistance.
• Class O in accordance Part B Building regulations 2000
  (as amended)


Click here for Detailed Diagram

 
 
 
  GRANOL TS RAIL SYSTEM WITH 15mm DRAINAGE GAP  
 

 

 

 

SPECIFACTION
• 15mm Firecheck
• 100mm Lightweight Steel Studs Containing 50mm Rockwool Flexi
• 10mm Cement Particle Board
• 15mm drainage gap
• 3mm-5mmGranol G Adhesive Mortar
• 70mm EPS with mineral wool fire breaks
• 3mm-5mm Granol-G Basecoat incorporating Plastic coated glass fibre
  reinforcing mesh
• Granol Acrylic or Silicone primer
• Granol Silicone or Acrylic Top coat

 

THERMAL
• Minimum U-Value 0.2 8W/(m2K) ACOUSTIC
• Minimum sound insulation 50RwdB sound reduction FIRE
• 60 minutes fire resistance.
• Class O in accordance Part B Building regulations 2000 (as amended)
• BS8414 Part 2 Compliant

 

 

 

NHBC APPROVED

Click here for Detailed Diagram

 

 